4001 Particle-Into-Liquid-Sampler with control software
PILS-AC Auto-collector with either 80 or 38 vial holding carousel and
control software
CA80 Additional 80 vial-holding carousel for Auto-Collector and
1.2 or 2.0 ml vials
CA38 Additional 38 vial-holding carousel for Auto-Collector and 10
or 12 ml vials
VS1.2 Pack of 1000, 1.2 ml poly vials and caps with septa
VS2.0 Pack of 1000, 2.0 ml glass vials and caps with septa
VM10 Pack of 1000, 10 ml glass vials and caps with septa
VM12 Pack of 1000, 12 ml poly vials and caps with septa
CR Crimping tool for 10 ml glass vial aluminum caps
(required with VM10)
DE Denuder package with three denuders for organic, acidic
and basic gases
8003 Round Jet Impactor with 1.0 micrometer cut size, 15 lpm flow
8005 Round Jet Impactor with 2.5 micrometer cut size, 15 lpm flow
8006 Round Jet Impactor with 10 micrometer cut size, 15 lpm flow
PILS-P115 External vacuum pump, 115 V
PILS-P230 External vacuum pump, 230 V
PILS-PC Computer with 4001 PILS software
PILS-Kit Maintenance Kit for 4001 PILS
Specifications
Parameter Value
PILS inlet sample flow 11-15 lpm
Washflow and sample liquid flow rates 0.03-2.0 ml/min
Chemical Species Detected
SO4, NO3, NO2, Cl, NH4, K, Na, Ca,
Mg detection limits 100 ng/m³
Acetate, formate and oxalate organic
acids detection limit 50 ng/m³
Water soluble organic carbon
detection limit 10 ppb
Electrical
Supply voltage 110 OR 230 VAC
Supply current 5 amps @ 110 VAC
Operating temperature range 15-35°C
Physical
Dimensions 17.2 x 6.9 x 16 in/43.25 x17.5 x 4.75 cm
PILS system total weight 20 lbs/9 kg
Auto-collector total weight 20 lbs/9 kg
Providing Aerosol Measurement Solutions
Copyright ©2017 All specifications are subject to change without notice. BMI assumes no responsibility for inaccuracies in this document
or for any obligation to update information in this document. BMI reserves the right to change, modify, transfer or otherwise revise this
publication without prior notice.
*Some products may be shown with optional accessories, which are sold separately. Items shown may not be to scale.
Publication:
R. J. Weber, D. Orsini, Z. Yhuang, Y. N. Lee, P. J. Klotz, and F. J. Brechtel (2001).
A Particle-into-Liquid Collector for Rapid Measurement of Aerosol Bulk Chemical
Composition. Aerosol Science and Technology, 35, 718-727.
A. Sorooshian, F. J. Brechtel, Y. Ma, R. J. Weber, A. Corless, R. C. Flagan, and J. H.
Seinfeld (2006). Modeling and Characterization of a Modified Particle-into-liquidSampler
(PILS) Optimized for Aircraft Sampling, Aerosol Science and Technology, 40:
396-409.
Auto-collector with 80-vial holding carousel